1. Only the surface temperature is measured, and the infrared thermometer cannot measure the internal temperature.
2. The wavelength above 5um cannot be measured through quartz glass. Glass has very special reflection and transmission characteristics, and accurate infrared temperature readings are not allowed. However, the temperature can be measured through the infrared window. Infrared thermometers should preferably not be used for temperature measurement on shiny or polished metal surfaces (stainless steel, aluminum, etc.).
3. Locate the hot spot. To find the hot spot, the instrument should aim at the target, and then scan the target up and down until the hot spot is determined.
4. Pay attention to environmental conditions: steam, dust, smoke, etc. It blocks the optics of the instrument and prevents accurate temperature measurement.
5. Ambient temperature, if the thermometer is suddenly exposed to an ambient temperature difference of 20°C or higher, allow the instrument to adjust to the new ambient temperature within 20 minutes.